Maintenance Manual Electromechanical Devices
____________________________________________________________________________________________
7.1 Overview
This chapter describes all the electromechanical parts of the printer with their main electrical
and mechanical requirements to allow the field service technicians to check the correct
functioning.
7.1.1 Print Head
The print head installed on this printer is an electromagnetic non-ballistic type.
The needles of the 24-pin printhead have diameter of 0.2 mm (0.0087") and they are
positioned in a diamond layout in which the odd pins (1÷23) are positioned in the right row
with the vertical pitch of each row of 0.282 mm (1/90").
Needle 1 is the top most of right row, needle 2 is the top most of the left row.
ELECTRICAL REQUIREMENTS
Coil resistance 5.0 ± 10% measured at 25°
Thermal sensor 1000 ± 6% measured at 25°
(see table below)
Temperature (°C) Resistance ()
10 887
20 961
25 1000
30 1039
40 1121
50 1206
60 1295
70 1387
80 1483
90 1583
100 1687
110 1794
120 1905
130 2020
140 2138
150 2260
Table 7.1 Print Head Resistance/Temperature Characteristics
____________________________________________________________________________________________