Chapter 12: Removal and Replacement Procedures --- Fuser and Paper Exit
12-7
RRP 4.3 Exit Chute
Removal
1. Remove all of the covers except the Front Transport Assembly.
2. Remove the Fuser Assembly (RRP 4.1).
3. Remove the Pressure Roll (RRP 4.2).
4. Remove the two 8mm gold collar screws and springs securing the Exit
Chute to the Fuser Assembly .
5. Remove the Exit Chute.
Replacement
1. Position the Exit Chute on top of the heat roller the Heat Roll, threading
the Exit Actuator through the rectangular hole in the center of the Chute.
2.
NOTE: Make sure the holes at the ends of the Exit Chute line up with the
bosses on the base of the Fuser Assembly.
3. Reinstall the two 8mm gold collar screws and springs securing the Exit
Chute to the Fuser Assembly.
4. Reinstall the Pressure Roll.
5. Reinstall the Fuser Assembly.
6. Reinstall the covers.